Quad Power Gallon

NSF APPROVED, METAL AND ROOF SAFE, MULTI-USE COIL CLEANER – Quad Power contains the latest and greatest in surfactant and inhibitor chemical technology creating a coil cleaner in a class by itself. It has the ability to quickly dissolve contaminants and deodorize coils while remaining truly metal and rubber safe. It is perfect for micro-channels, mini-splits, evaporators, condensers, electronic air filters, and more.

QUAD POWER GALLON

Versatile and Powerful Cleaning Solution

QUAD POWER is a highly concentrated, cost-effective cleaning solution available in various sizes to meet your needs.This powerful formula effectively removes grease, grime, and dirt from a wide range of surfaces, making it an essential tool for HVACR contractors and their clients.

Key Features and Benefits:
  • Versatile Applications: Cleans microchannels, mini splits, air-cooled condensers, evaporator coils, permanent filters, fan blades, motors, and other equipment.
  • Powerful Cleaning Action: Removes stubborn grease, grime, and dirt.
  • Deodorizing Properties: Eliminates unpleasant odors.
  • Safe and Effective: Safe for use on rubber, membrane, and metal roofs.
  • NSF Approved: Meets NSF standards for safety and effectiveness.

QUAD POWER is available in multiple formats, including a pre-mixed gallon bottle, a spray bottle, an aerosol spray,and a 5-gallon jug. Choose the size that best suits your needs.

Experience the power of QUAD POWER and restore your equipment to its optimal performance.

Part Number;                  Size
  • QP-1                                    5 gallons
Directions:

Effective Cleaning for HVAC Systems

General Precautions:
  • Wear Protective Gear: Always wear goggles, gloves, and protective clothing.
  • Turn Off System: Shut down the HVAC system before cleaning.
Condensers:
  1. Dilute: Mix 4 parts water with 1 part QUAD POWER.
  2. Prepare Sprayer: Add water and cleaner to the sprayer.
  3. Spray Coil: Spray the solution onto the dirty surface.
  4. Soak: Let the solution sit for 5-7 minutes.
  5. Rinse: Rinse with water.
  6. Clean Sprayer: Rinse out the sprayer, wand, and nozzle.
  7. Repeat: For extremely dirty coils, consider a second application.
Evaporators/Mini Splits/Micro Channels:
  1. Dilute: Mix 10 parts water with 1 part QUAD POWER.
  2. Spray and Soak: Apply the solution to the dirty surface and let it soak for 5-10 minutes.
  3. Resume Operation: Return the system to operation. Condensation will rinse away the solution.
  4. Clean Sprayer: Rinse out the sprayer, wand, and nozzle.
  5. Repeat: For extremely dirty coils, consider a second application.
Permanent Filters:
  1. Prepare Solution: For every gallon of water, add 1 ounce of QUAD POWER.
  2. Soak: Soak the greasy components in the solution for at least 15 minutes.
  3. Rinse: Rinse with water.
Quad Power Aerosol:
  1. Wear Protective Gear: Ensure you’re wearing goggles, gloves, and protective clothing.
  2. Shake Can: Shake the canister well.
  3. Spray: Remove the cap and spray the solution onto the surface.
  4. Wait: Allow the foam to liquefy for 5-10 minutes.
  5. Rinse: Rinse the surface with water.
Note on Roofing Materials:
  • Test Before Cleaning: Due to potential effects on color and finish, test QUAD POWER on a small area of the roof before cleaning.
  • Rubber Roofs: QUAD POWER is generally safe for rubber and membrane roofs, but test on a small area first.

By following these directions, you can effectively clean and maintain your HVAC system using QUAD POWER.

 

DANGERS & PRECAUTIONS:

Do not get in eyes, on the skin, or on clothing. Avoid breathing dust/fume/ gas/mist/vapors/spray. Wash skin thoroughly after handling. Do not eat, drink or smoke when using this product. Use only outdoors or in a well-ventilated area. Wear protective gloves/eye protection/face protection.

Contact Us

News and Updates

Subscribe on Youtube

Follow Us on Facebook 

SDS-Aerosol

QPA-1-SDS.pdf

SDS-Liquid

Quad-Power-SDS-Updated-In-House-Formula.pdf

TDR

Quad-Power-TDR-copy-2.pdf

Studio Photos

Spanish Instructions

Instrucciones de uso: El producto debe usarse siguiendo las instrucciones proporcionadas y es exclusivo para profesionales de HVACR.
1) Se recomienda usar gafas protectoras, guantes y otras prendas de protección al usar este producto. El sistema debe estar apagado.
2) Se recomienda aplicar con cualquier pulverizador Vapco de la serie STW, pistola de extremo de manguera (HEG-1) o tanque pequeño (TTC-1).
Condensadores:
3) Para suciedad difícil, prepare la solución de limpieza mezclando cuatro partes de agua con una parte de Quad Power. Añada primero agua al pulverizador y luego añada Quad Power.
4) Rocíe la solución Quad Power sobre la superficie sucia y déjela actuar de 5 a 7 minutos.
5) Enjuague bien con agua.
6) Enjuague el pulverizador, la varilla de pulverización y la boquilla.
7) Cuando el recipiente esté vacío, enjuáguelo, vuelva a colocar la tapa y deséchelo de forma adecuada. **Para serpentines extremadamente sucios, podría ser necesaria una segunda aplicación. Evaporadores/Mini Splits/Microcanales: *Limpieza de los serpentines del evaporador en un entorno sin enjuague.
3) Prepare una solución de limpieza con 10 partes de agua y una parte de Quad Power y aplíquela con un rociador. Úsela solo en entornos sin enjuague con suficiente humedad condensada del aire para facilitar el enjuague.
4) Rocíe la solución Quad Power sobre la superficie sucia y deje actuar de 5 a 10 minutos.
5) Vuelva a poner el sistema en funcionamiento para que la condensación enjuague el Quad Power.
6) Enjuague el rociador, la varilla rociadora y la boquilla.
7) Cuando el recipiente esté vacío, enjuáguelo, vuelva a colocar la tapa y deséchelo de forma adecuada.
**Para serpentines extremadamente sucios, podría ser necesaria una segunda aplicación.
Filtros permanentes: Para limpiar componentes grasosos en un lavabo o tina, agregue una onza de Quad Power por cada galón de agua. Deje las piezas en remojo durante 15 minutos y luego enjuague bien con agua.

Efecto en los materiales del techo: Dependiendo de su composición y estado, el color y el acabado del material del techo pueden verse afectados por los limpiadores de serpentines. Se recomienda probar este limpiador en una pequeña área del techo antes de limpiarlo.

Techos de caucho: En general, este limpiador es seguro en techos de caucho y membrana. Si el techo está impregnado con virutas de aluminio, recomendamos probar en una pequeña área antes de limpiarlo.

 

Spanish Warnings/Precautions

Consejos de precaución: No respirar el polvo/humo/gas/niebla/vapores/aerosol. Lavarse bien las manos después de manipular este producto.
No comer, beber ni fumar mientras se utiliza este producto. Usar guantes/ropa/protección ocular/protección facial.
EN CASO DE INGESTIÓN: Llamar a un CENTRO DE TOXICOLOGÍA/médico si se encuentra mal. EN CASO DE INGESTIÓN: Enjuagarse la boca. NO provocar el vómito.
EN CASO DE CONTACTO CON LA PIEL (o el pelo): Quitarse inmediatamente la ropa contaminada. Enjuagarse la piel con agua/ducharse. EN CASO DE INHALACIÓN: Transportar a la persona al exterior y mantenerla en una posición que le facilite la respiración. EN CASO DE CONTACTO CON LOS OJOS: Enjuagar cuidadosamente con agua durante varios minutos. Quitar las lentes de contacto si lleva y resulta fácil. Seguir enjuagando. Llamar inmediatamente a un CENTRO DE TOXICOLOGÍA/médico. Enjuagarse la boca. Lavar la ropa contaminada antes de volver a usarla. Guardar bajo llave. Eliminar el contenido/el recipiente según las especificaciones de la normativa local, regional, nacional e internacional.