Low Temp Bubbles LDL -1/2P, 1Q, 1

LOW TEMP BUBBLES – is a leak detector formulated to be used above or down to -5°F. Will not harm metals, plastics, rubber, or other materials. Suitable for most refrigerants and other natural gas systems. Fluorescent dye increases the visibility of bubbles. LDL stands for Leak Detector LowTemp and this product is ideal for detecting even the smallest of leaks in colder environments while being easy to see when bubbles form.

LOW TEMP BUBBLES

Reliable Leak Detection in Low Temperature Environments

LOW TEMP BUBBLES is a versatile leak detector designed to work effectively in both hot and cold environments, down to -5°F. Its unique formulation is gentle on materials, ensuring it corrode harm metals, plastics, rubber, or other components. LDL stands for Leak Detector LowTemp and this product is ideal for detecting even the smallest of leaks in colder environments while being easy to see when bubbles form.

Key Features and Benefits:

  • Bubble Action Detection: Accurately identifies leaks, both large and small.
  • Locates Pressure Leaks: Pinpoints the exact source of leaks.
  • All-Temperature Performance: Works reliably in a wide range of temperatures.
  • Suitable for Most Systems: Compatible with various refrigerants and natural gas systems.
  • Fluorescent Dye: Enhances visibility for easy leak identification.

Part Number;                  Size

  • LDL-1/2P                           8 oz with dauber – 12/cs
  • LDL-1Q                              32 oz with sprayer – 12/cs
  • LDL-1                                 1 gallon – 4/cs

Directions:

This product must be used in accordance with the following directions and by professionals only.
  1. Safety First: Consult the Material Safety Data Sheet (MSDS) for important safety information.
  2. Apply Liberally: Daub or spray LOW TEMP BUBBLES generously around suspected leak locations.
  3. Look for Bubbles: If a leak is present, bubbles will form quickly, be sure to check back and bottom of connections and joints. Wait a minimum of 5 minutes for micro leaks.
  4. Leak Sealants: If leaks are present, consider Vapco Xpress Injects to help seal leaks permanently where appropriate.

 

 

Contact Us

News and Updates

Subscribe on Youtube

Follow Us on Facebook 

 


 

SDS

LOW TEMP BUBBLES SDS REV. 1

Identification & Supplier Details

Product Identification (Section 1)

Product Name Low Temp Bubbles
Product Number/Brand LDL-1, LDL-1/2P, LDL-1Q (Brand: Vapco)
Recommended Use Low temperature leak detector

Supplier Details

Name Vapco Products, Inc.
Address 401 Marshall Road, Valley Park, Missouri 63088, United States
Telephone / Fax / Email (636) 923-2121 / (636) 923-3002 / [email protected]
Emergency Phone Number (800) 255-3924

Hazard Identification & Composition

GHS Classification (Section 2)

Key Hazards (OSHA 29 CFR 1910.1200) Acute toxicity, oral, Cat. 4; Eye irritation, Cat. 2B; Skin irritation, Cat. 2
STOT (single exposure), Cat. 1; STOT (repeated exposure), Cat. 2
Signal Word Warning
Hazard Statement(s) H302: Harmful if swallowed
H315: Causes skin irritation
H320: Causes eye irritation
H370: Causes damage to organs [Central nervous system, Kidneys] by ingestion.
H373: May cause damage to organs [Kidneys] through prolonged or repeated exposure [if swallowed].
Key Precautionary Statement(s) P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P270: Do not eat, drink or smoke when using this product.
P308+P311: IF exposed or concerned: Call a POISON CENTER/doctor.
P405: Store locked up.

Hazardous Components (Mixtures) (Section 3)

Component Name CAS Number Concentration (wt%)
Ethylene glycol 107-21-1 20 – 30 %
Alkylphenol ethoxylate 127087-87-0 5 – 15 %

Physical & Chemical Properties

Physical State / Appearance Liquid / Turbid liquid
Color / Odor Green / Bland
Boiling Point / Flammability >212°F (100°C) / Not considered a flammable liquid
Solubility in Water Soluble in water
Vapor Pressure / Evaporation Rate 20 mmHg / <1
Relative Density / Relative Vapor Density 1.00-1.02 / >2
pH / Kinematic Viscosity 8.5-9.5 / 135 cPs

Stability & Reactivity

Reactivity / Chemical Stability Stable under normal conditions of use.
Possibility of Hazardous Reactions None known.
Incompatible Materials Strong oxidizing agents.
Hazardous Decomposition Products Carbon oxide(s).

Toxicological Information

Acute & Chronic Effects (Section 11)

Acute Health Hazards (Ingestion) Harmful if swallowed. May cause convulsions, dizziness, nausea, vomiting, and abdominal pain.
STOT – Single Exposure Causes damage to organs: Central nervous system, Kidneys.
STOT – Repeated Exposure May cause damage to organs [Kidneys] through prolonged or repeated exposure (if swallowed).
Skin/Eye Irritation Causes skin irritation and eye irritation (tearing, redness, discomfort).

Toxicological Data (LD50)

Component Route Value
Ethylene glycol Oral (Rat) 4700 mg/kg
Alkylphenol ethoxylate Oral (Rat) 960-3980 mg/kg

First-Aid Measures

General Advice If exposed or concerned, get medical advice and attention. Show the label where possible.
If Swallowed (Critical) Rinse mouth. Do NOT induce vomiting. Call a POISON CENTER/doctor.
In Case of Skin Contact Wash with plenty of water for at least 15 minutes. Remove contaminated clothing. Obtain medical attention if irritation persists.
In Case of Eye Contact Rinse cautiously with water for several minutes. Remove contact lenses if present. Continue rinsing for at least 15 minutes. Obtain medical attention if irritation persists.
Special Treatment Needed (Antidotes) Treat symptomatically. Antidotes include ethyl alcohol or 4-Methylpyrazole (Fomepizole, Antizole) if toxic ingestion is suspected.

Fire-Fighting & Accidental Release Measures

Fire-Fighting Measures (Section 5)

Suitable Extinguishing Media Water spray, fog, $text{CO}_2$, alcohol-resistant foam, dry chemical, or sand.
Specific Hazards / Products None known. Hazardous Combustion Products: Carbon oxide(s).
Protection During Firefighting Wear NIOSH-approved Self-Contained Breathing Apparatus (SCBA) and full body protective clothing.

Accidental Release Measures (Section 6)

Personal Precautions Do not get in eyes, on skin, or on clothing. Do not breathe vapors/mist. Evacuate unnecessary personnel.
Containment/Clean-up Methods Ventilate the area. Contain spills with dikes or absorbents. Take up liquid spill into absorbent material. Transfer to a suitable container for disposal.
Environmental Precautions Prevent entry to sewers and public waters. Avoid release to the environment.

Handling, Storage & PPE

Handling Precautions (Section 7)

Safe Handling Do not handle until all safety precautions have been read. Wash hands before eating, drinking, or smoking. Do not breathe gas, mist, spray.
Additional Hazards Do not pressurize, cut, or weld containers. Keep out of reach of children.

Storage Conditions (Section 7)

General Conditions Store in a dry, cool, well-ventilated place. Keep only in the original container. Store locked up.
Incompatible Materials Keep/Store away from strong oxidizing agents.

Personal Protective Equipment (PPE) (Section 8)

Eye/Face Protection Chemical safety goggles. Emergency eye wash fountains/safety showers must be available.
Skin/Body Protection Protective gloves (Ethylene glycol has Skin designation in some regions) and suitable chemical resistant clothing.
Respiratory Protection Use a NIOSH-approved SCBA whenever exposure may exceed established OELs.

Transport & Regulatory Information

Transport Information (Section 14)

Regulation UN Number Class Proper Shipping Name
DOT (US) / IMDG / IATA UN3082 9 (Misc. Hazardous) Environmentally hazardous substance, liquid, n.o.s. (Packing Group: III)

Regulatory Information (Section 15)

California Prop. 65 Warning Contains Ethylene glycol (ingested), known to cause birth defects or other reproductive harm.
Right To Know Components Ethylene glycol (107-21-1) is listed on MA, NJ, and PA Right To Know Lists. Alkylphenol ethoxylate (127087-87-0) is on the MA TURA list.

Disposal & Ecological Information

Disposal Considerations (Section 13)

Product Disposal Dispose of contents/container in accordance with local, regional, national, and international regulations.
Sewage Disposal Avoid release into the environment. Keep out of sewers and waterways.

Ecological Information (Section 12)

Toxicity to Aquatic Life Ethylene glycol has high LC50 values (low toxicity). Alkylphenol ethoxylate has lower LC50 values (higher toxicity).
Degradability / Bioaccumulation Product is biodegradable. Not expected to bioaccumulate.
Mobility in Soil This product is mobile in soil.

Disclaimer & Preparation Information

Disclaimer Summary Information is accurate to the best of our knowledge, but no assumption of liability is made for accuracy or completeness. Final determination of suitability is the sole responsibility of the user.
Preparation Information (Section 16) Prepared by: Jessica Wilson
Date prepared: 3/18/2025

 

TDR