PVC Spray ‘N Lock Clear PVC-SNLC

Revolutionary PVC Aerosol Fusion Product –  Not a Cement or Glue, No Daubers or Primers Required

  • PVC SPRAY ’N LOCK – is an amazing evolution in bonding PVC, CPVC, DWV,  ABS, and Cellular Core PVC. Completely eliminate the need for messy, two-step primers and cements and upgrade to a cleaner and easier way to permanently bond PVC material together. Pressure tested to 215 PSI, heat tested to 140°F and certified to not negatively impact potable water, PVC SPRAY ’N LOCK works in hot, cold, wet, or dry conditions. Recommended on 3” PVC and smaller.

Independent Laboratory Test Results (Potability and Pressure Test): Click here

Article

PVC Spray ‘N Lock Clear

Revolutionary PVC Pipe and Fitting Adhesive

PVC Spray ‘N Lock is a powerful and innovative adhesive designed to simplify the construction and repair of potable and non-potable PVC systems. Its unique formula provides a fast, reliable, and permanent bond without the need for primers or daubers.

Key Features and Benefits:
  • Rapid Curing: Forms a permanent bond in seconds.
  • Versatile Conditions: Works in wet, dry, hot, or cold conditions.
  • Safe for Potable Water: Does not negatively impact the potability of water.
  • Ideal for HVACR Applications: Perfect for drain lines and venting.
  • High-Yield Formula: One can can bond over 100 fittings and pipes of 3/4″.

PVC Spray ‘N Lock is a game-changer for contractors, professionals, and hobbyists seeking a faster, easier, and more efficient way to work with PVC. Its exceptional performance and ease of use make it a valuable tool for a variety of applications.

Available Colors: Industry purple and professional clear

Note: For optimal results, follow the provided directions and safety precautions.

PVC Spray ‘N Lock Part Number;      Size
  • PVC – SNLC                                       10 oz 12/cs

(This PVC Spray ‘N Lock display is available at no extra charge and comes with 2 cases of clear and 2 cases of purple. It holds 40 cans with 10 on each row and is a great way to bring attention to a new product)

Directions:

Effective PVC Pipe and Fitting Bonding

Before Use:
  • Read Warnings and Directions: Carefully review the product label for safety information.
  • Take Precautions: Handle with care, as the product is flammable.
Application:
  1. Cut Pipe Square: Ensure the pipe is cut squarely.
  2. Remove Debris: Remove any dirt or burrs from the pipe and fitting.
  3. Dry Fit: Fit the pipe into the fitting to ensure proper alignment.
  4. Mark Pipe: Mark the pipe for alignment.
  5. Spray: Spray both the pipe and fitting with PVC Spray ‘N Lock.
  6. Insert and Turn: Insert the pipe into the fitting and turn 1/4 turn.
  7. Hold: Hold the pipe in place for 10 seconds.
  8. Repeat for Other Joints: Follow the same steps for remaining joints.

Additional Tips:

  • Ensure Wet Surfaces: Make sure both the pipe and fitting are thoroughly wet with the product before connecting.
  • Recommended Pipe Size: For best results, use on pipe 3″ and smaller.

By following these directions, you can effectively bond PVC pipe and fittings using PVC Spray ‘N Lock.

 

The product works on both dry and wet PVC pipes!

NOTE: Product designed to bond SIMILAR PVC COMPONENTS; results vary if DISSIMILAR types are used. The product dries rapidly. Make sure PVC pipe and fitting are saturated with the product before connecting. For best results, use on 3” and under pipes made of matching material.

Certified not to negatively impact the potability of water, ASTM D3452-06(2017).

Colder temperatures require more time to cure.

 

 

DANGERS & PRECAUTIONS:

This product contains a hydrocarbon propellant, petrochemical solvents, Methyl Ethyl Keton. Keep away from all children and untrained personnel. Keep away from heat, hot surfaces, sparks, and open flames. No smoking. The container temperature should not exceed 120F. Protect from sunlight. DO NOT drop. Harmful or fatal if swallowed or ingested. DO NOT HUFF.

 

Contact Us

News and Updates

Subscribe on Youtube

Follow Us on Facebook 

SDS

⚠️ PVC SPRAY N LOCK SDS

1. Identification & Supplier Details

Product Name PVC SPRAY ‘N LOCK
Product Numbers PVC-SNLC, PVC-SCLP
Brand Vapco
Recommended Use Spray-on PVC bonding agent
Supplier Vapco Products, Inc.
401 Marshall Road
Valley Park, Missouri 63088 United States
Contact Information Phone: (636) 923-2121
Fax: (636) 923-3002
Email: [email protected]
Emergency Phone (800) 255-3924

2. Hazard Identification & Composition

GHS Classification Eye damage/irritation, Cat. 2A
Flammable aerosols, Cat. 1
Gases under pressure, liquefied gas
Specific target organ toxicity (single exposure), Cat. 3
Signal Word DANGER
Hazard Statements H222: Extremely flammable aerosol
H280: Contains gas under pressure; may explode if heated
H319: Causes serious eye irritation
H336: May cause drowsiness or dizziness
Precautionary Statements P210: Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P211: Do not spray on an open flame or other ignition source.
P251: Pressurized container: do not pierce or burn, even after use.
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P280: Wear eye protection/face protection.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes.
P410+P412: Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
Hazardous Component CAS No. Concentration
Methyl ethyl ketone (MEK) 78-93-3 50 – 75 % (weight)
Propane, liquid 74-98-6 50 – 75 % (weight)

3. Physical & Chemical Properties

Physical State / Appearance Liquid / Aerosol spray (Colorless)
Odor Characteristic ketone odor
Freezing Point -176.67°C (-286°F)
Boiling Point -37.8°C (-36.1°F)
Flash Point N/D (Extremely Flammable)
Explosion Limits LEL: 2.5% / UEL: 9.0%
Vapor Pressure 586.05 kPa (85 psi) at 21.1°C (70°F)
Relative Density 0.53
Solubility Insoluble in water

4. Stability & Reactivity

Chemical Stability Stable under recommended handling and storage conditions.
Reactivity Contains gas under pressure; may explode if heated. Vapors may ignite via static discharge.
Conditions to Avoid Direct sunlight, extreme temperatures, open flames, sparks, or static discharge.
Incompatible Materials Strong oxidizing agents, strong caustics, and hydrogen peroxide.
Hazardous Decomposition Carbon oxide(s).

5. Toxicological Information

Acute Toxicity MEK: LD50 Oral (Rat): 2.6 g/kg; LD50 Dermal (Rabbit): 6.4 g/kg; LC50 Inhalation (Rat): 11300 ppm (4hr)
Propane: LC50 Inhalation (Rat): 658 mg/l (4hr)
Eye Contact Causes serious eye irritation, redness, tearing, and blurred vision.
Inhalation Effects May cause CNS depression (dizziness, drowsiness, headache). High concentrations may cause asphyxiation or death.
Skin Contact May cause localized defatting and drying with prolonged contact.
Carcinogenicity / Mutagenicity Not classified.

6. First-Aid Measures

General Advice Never give anything by mouth to an unconscious person. Seek medical advice if you feel unwell.
If Inhaled Remove to fresh air. Keep at rest in a comfortable breathing position. Call a POISON CENTER if unwell.
If On Skin Drench with water for 15 minutes. Remove contaminated clothing. Seek medical attention if irritation persists.
If In Eyes Rinse with water for at least 15 minutes. Remove contact lenses. Seek medical attention if irritation persists.
If Swallowed Rinse mouth. Do NOT induce vomiting. Obtain medical attention.

7. Fire-Fighting & Accidental Release Measures

Extinguishing Media CO2, alcohol-resistant foam, dry chemical, or sand.
Fire Hazards Extremely flammable. Container may explode in heat. Vapors are heavier than air and may flash back.
Fire Fighting Protection Wear NIOSH-approved SCBA and full body protective clothing. Fight fire remotely due to explosion risk.
Accidental Release Eliminate all ignition sources. Ventilate area. Evacuate unnecessary personnel. Stop leak if safe. Absorb liquid spills and transfer to disposal container.

8. Handling, Storage & PPE

Safe Handling Do not handle until all safety precautions are read. Avoid contact with eyes and skin. Do not breathe gas/mist. Keep away from ignition sources. Do not pierce or burn.
Storage Conditions Store in a dry, cool, well-ventilated place locked up. Protect from sunlight. Do not exceed 50°C/122°F. Keep away from incompatible materials.
Exposure Controls Limit Values
Propane (OSHA/NIOSH) PEL/REL: 1000 ppm (1800 mg/m3)
MEK (OSHA PEL) TWA: 200 ppm (590 mg/m3)
MEK (NIOSH REL) TWA: 200 ppm; STEL: 300 ppm
Personal Protection (PPE) Eyes: Chemical safety goggles.
Skin/Body: Protective gloves and fire/flame resistant clothing.
Respiratory: NIOSH-approved SCBA if exposure exceeds limits.

9. Transport & Regulatory Information

DOT / IMDG / IATA UN Number: UN1950
Class: 2.1 (Flammable Gas)
Shipping Name: Aerosols, flammable, (each not exceeding 1 L capacity)
State Regulations MA, NJ, PA: Propane and 2-Butanone (MEK) are listed.
TSCA Inventory All components are listed on the US EPA TSCA public inventory.

10. Disposal & Ecological Information

Ecotoxicity MEK: LC50 (Pimephales promelas) 3130-3320 mg/L. Hazardous to the aquatic environment.
Degradability Readily biodegradable.
Disposal Methods Dispose in accordance with local/national regulations. Do not puncture or incinerate containers. Keep out of sewers.

11. Disclaimer & Preparation Information

Disclaimer Information is accurate to the best of our knowledge. No warranty is expressed or implied. Users are responsible for safe use and compliance.
Prepared By Jessica Wilson
Date Prepared 8/6/2025

Lab Tests

19C0268-1.pdf

Studio Photos