Refrigerant Can Tap RCT- 7/16, X12

The Vapco Refrigerant Can Tap (RCT-716) is a durable, professional-grade can actuator equipped with a specialized 7/16″ fitting for use with Vapco’s 7/16″ R290 and R600a. It is specifically designed for technicians using manifold gauge sets or charging hoses for servicing systems with R-290 and R-600a hydrocarbon refrigerants. Constructed from heavy-duty stainless steel and brass, this tool provides a direct, secure, and reliable connection from can to hose.

REFRIGERANT CAN TAP 7/16″ 

Engineered for precision and longevity, the RCT-7/16 eliminates the need for adapters when working with 7/16″ resealable can fittings. Its robust construction ensures it can handle the daily demands of field service, providing a leak-free seal and precise refrigerant flow control. The simple screw-on design and an easy-to-grip T-handle allow for smooth depression and valve operation, making it an essential tool for efficient and professional service of systems requiring R-290 or R-600a.

Key Features & Benefits

  1. Specialized 7/16″ Fitting: Connects directly to compatible manifold gauge sets and charging hoses without the need for additional adapters.
  2. Durable Brass & Steel Construction: Built to withstand rigorous daily use in professional environments, ensuring long-term reliability.
  3. Simple Screw-On Application: Ensures a fast, secure, and gas-tight seal on standard R-290 and R-600a cans.
  4. Precision T-Handle Control: Allows for the effortless piercing of the can’s seal and provides fine control over refrigerant flow.
  5. Optimized for Hydrocarbon Refrigerants: Specifically designed for the service requirements of R-290 and R-600a systems.

Part Number

  • RCT-7/16                             1ea
  • RCT-7/16-X12                    12/cs         
  • FOR USE WITH:
    • 7/16” Fitting R290- 8OZ (YELLOW LABEL)
    • 7/16″ Fitting R600a-6OZ (YELLOW LABEL)
Professional Application Protocol (For Certified Technicians Only)

Guidelines for Use

IMPORTANT: You must check and repair all leaks before charging. Read and understand all product warnings and directions before use. As with any flammable substance, the use of spark-proof tools and adequate ventilation is required. Take all necessary safety precautions.

  1. Assemble Tools: With the valve handle turned fully counter-clockwise (retracted), firmly screw the can tap onto the refrigerant can. Attach a compatible charging hose to the tap’s 1/4″ flare fitting.
  2. Connect to System: Connect the charging hose to the low-pressure side ONLY.
  3. Charge System: Pierce the can by turning the valve handle clockwise. Retract the handle and invert the can to allow flow and charge the system by weight according to the manufacturer’s specifications. Use a digital scale for accuracy.
  4. DO NOT OVERCHARGE THE SYSTEM. A precise charge is critical.
  5. Disposal: After use, dispose of the empty can and any remaining material in accordance with all local, state, and federal regulations.

Contact Us