Xpress Inject System Protect XPS-5T-P

SYSTEM PROTECT is a specialized, direct-inject HVAC acid neutralizer additive formulated to prevent moisture and acid damage inside the refrigerant circuit. It actively neutralizes and converts acids, then cleans and removes acidic residue—helping maintain the integrity and efficiency of refrigerant lines. Xpress Inject delivery installs in minutes with no mess. Compatible with all refrigerants except ammonia. Ideal for preventive maintenance HVAC programs, tune-ups, and service calls.

 

SYSTEM PROTECT

System Protect | HVAC Acid Neutralizer & Moisture Protection

SYSTEM PROTECT: an integral part of the Xpress Inject family, System Protect targets the root causes of corrosion and component wear associated with moisture and acid formation. By neutralizing acids and clearing residue, it helps keep systems cleaner and more stable over time—an ideal preventive maintenance step for both new and aging residential systems. If you’re searching for HVAC moisture and acid protection, a refrigeration acid neutralizer or acid scavenger additive, or a refrigerant line cleaner, System Protect delivers fast, consistent dosing with no extra steps.

Key Features and Benefits:

  • Prevents and eliminates acid in refrigerant lines
  • Removes and moisture from lines
  • Helps maintain system integrity and operating efficiency
  • Direct-inject format (Xpress Inject) for fast, clean installation
  • Compatible with all refrigerants, excluding ammonia
  • Suitable for preventive maintenance on new installs and service calls
  • Part number: XPS-5T-P; treats systems up to 5 tons per tube

Part Number

  • XPS-5T-P                        Up to 5 Ton 4/cs

Previously called:  XPress Dry; XPS-DRY

Compatible with all refrigerants, excluding ammonia.

Directions – HVAC System Protect:

This product must be used in accordance with the following directions and by professionals only.

Always read the product label and Safety Data Sheet (SDS) for complete precautionary and first aid information before use.

System Enhance is designed for quick and effective leak sealing in HVACR systems. Choose the method below that best suits your equipment and job site conditions.

General Safety & Pre-Installation Checks (Applicable to All Methods)

Before beginning, ensure the system is ready and you have the correct System Enhance product for the system’s tonnage.

  1. Safety First: Always wear appropriate personal protective equipment (PPE), including safety glasses and protective gloves, when working with refrigerants and sealants.
  2. Identify Ports: Clearly identify the low-side (suction) and high-side (liquid) service ports on the system.
  3. System Running & Mode:
    • Ensure the HVACR system is powered on and running, with the compressor engaged.
    • If working on a heat pump, set the system to Cooling Mode for optimal sealant distribution.
  4. System Charge: Verify the system has an adequate refrigerant charge. System Enhance can be injected into a fully charged or partially low system; if significantly low, you may use refrigerant to push the sealant (see Traditional Method alternative).
  5. Refrigerant Compatibility: Confirm the system is NOT an ammonia (NH3) system, as System Enhance is not compatible.
  6. Xpress Overhaul Size: Ensure you have selected the appropriate System Enhance cartridge size for the system’s tonnage (e.g., XPS-Mini, XPS-5T, XPS-60T).
  7. Inspect Xpress Inject Tube: Do not bend, cut, or deform the tube. Check to ensure small nitrogen bubble is present and free moving in the tube.

 

After injecting System Enhance, it’s crucial to allow the product to fully circulate and activate:

  1. Run Time: Run the AC unit for a minimum of one (1) hour immediately after injecting System Enhance. This ensures thorough circulation of the sealant throughout the system. For larger systems or very cold conditions, allow for even longer run times (e.g., 2-4 hours).
  2. System Monitoring: Monitor the system’s operating pressures and temperatures. System Enhance is designed not to alter system performance or clog metering devices.
  3. Leak Verification: After the recommended run time, verify leak resolution using standard diagnostic methods.
  4. Documentation: Document the application of System Enhance in the system’s service log, including date, product size, and method used.
Important Notes for Professionals
  • Refrigerant Charging Concurrent with Sealant: If the system is low on refrigerant, System Enhance can be injected concurrently with refrigerant charging. Simply connect the inject to the service port and push the sealant into the system using the refrigerant being added, following the appropriate method.
  • No Pump Down Required: System Enhance does not require pumping down the system for injection, regardless of refrigerant type.
  • Polymer-Free Formulation: System Enhance is formulated to be “polymer free” while in the tube and circulating through the system, protecting sensitive system components.

 

 

 

 

Contact Us

News and Updates

Subscribe on Youtube

Follow Us on Facebook 

 


 

SDS

⚠️ SYSTEM PROTECT EXPRESS INJECT-SDS – DOWNLOAD

1. Identification & Supplier Details

Product Name Xpress Inject System Protect
Product Number XPS-5T-P, XPS-250T-P
Brand Vapco
Recommended Use Eliminates moisture in an air conditioning system
Supplier Vapco Products, Inc.

401 Marshall Road, Valley Park, MO 63088, United States

Telephone / Fax (636) 923-2121 / (636) 923-3002
Emergency Phone (800) 255-3924 (ChemTel)

2. Hazard Identification & Composition

GHS Classification Eye damage/irritation, Cat. 2A; Flammable liquids, Cat. 2
Signal Word DANGER
Hazard Statements H225: Highly flammable liquid and vapor

H319: Causes serious eye irritation

Other Hazards Exposure may aggravate pre-existing eye, skin, or respiratory conditions.
Hazardous Component CAS No. Concentration
Ethanol 64-17-5 100 % (weight)

3. Physical & Chemical Properties

Physical State Liquid Flash Point 13°C (55°F)
Boiling Point 78°C (173°F) Melting Point -114°C (-173°F)
Density 0.7893 g/cm3 at 20°C Auto-ignition Temp 363°C (685°F)
Explosion Limits N/D Vapor Pressure N/D

4. Stability & Reactivity

Chemical Stability Highly flammable liquid and vapor. May form flammable/explosive vapor-air mixture.
Reactivity Hazardous reactions will not occur under normal conditions.
Conditions to Avoid Direct sunlight, extremely high/low temperatures, open flame, heat, sparks, and incompatible materials.
Incompatible Materials Strong acids, bases, and oxidizers. Zinc, Brass, Aluminum. Attacks some plastics and rubber.
Hazardous Decomp. Carbon oxide(s). May release flammable gases.

5. Toxicological Information

Acute Toxicity Ethyl alcohol: LD50 Oral (Rat): 7,060 mg/kg; LC50 Inhalation (Rat): 20,000 ppm (10h)
Eye Contact Causes serious eye irritation. Redness, pain, swelling, tearing, and blurred vision.
Skin/Inhalation May cause skin and respiratory irritation.
Chronic Effects None expected under normal conditions of use. Not classified for carcinogenicity or mutagenicity.

6. First-Aid Measures

Inhalation Remove to fresh air. Keep at rest in a comfortable position. Seek medical attention if unwell.
Skin Contact Drench with water for 15 minutes. Remove contaminated clothing. Seek medical attention if irritation persists.
Eye Contact Immediately rinse with water for at least 15 minutes. Remove contact lenses. Seek medical attention.
Ingestion Rinse mouth. Do NOT induce vomiting. Obtain medical attention immediately.

7. Fire-Fighting & Accidental Release Measures

Extinguishing Media Water spray, fog, CO2, alcohol-resistant foam, dry chemical, or sand.
Fire Hazards Container may explode in heat. Vapors are heavier than air and may travel to ignition sources.
Spill Clean-up Eliminate ignition sources. Ventilate area. Absorb with liquid-binding material and transfer to suitable container.

8. Handling, Storage & PPE

Safe Handling Avoid contact with eyes/skin. Do not breathe vapors. Use explosion-proof equipment. Ground containers.
Storage Store in original container in a cool, well-ventilated place away from ignition sources. Protect from sunlight.
PPE Chemical safety goggles, protective gloves, fire-retardant clothing, and NIOSH-approved SCBA if limits are exceeded.

9. Transport & Regulatory Information

DOT/IMDG/IATA UN1170, Class 3, PG II (Ethanol/Ethyl alcohol solutions)
SARA 311/312 Immediate (Acute) Health Hazard, Fire Hazard
CA Prop 65 WARNING: Contains chemicals known to cause cancer and birth defects.
Right to Know Ethanol and Toluene listed in MA, NJ, and PA.

10. Disposal & Ecological Information

Ecotoxicity Ethanol LC50 (Fish): >100 mg/l (96h); EC50 (Daphnia): 9268-14221 mg/l (48h).
Disposal Method Contact licensed waste service. Burn in chemical incinerator with care. Dispose of in accordance with all regulations.
Empty Containers May remain hazardous; do not puncture, flame cut, or incinerate.

11. Disclaimer & Preparation Information

Disclaimer The information contained herein is accurate to the best of our knowledge. No warranty, expressed or implied, is made. The user is responsible for compliance with all regulations.
Prepared By Jessica Wilson
Date Prepared 1/22/2026