Xpress Seal

SEAL – Unlike other products, Xpress Seal is able to form seals faster by traveling with refrigerant gas instead of oil. This specially formulated epoxy reacts to water and air when in contact with the atmosphere at the site of a leak.

 

 

XPRESS SEAL

Powerful and Efficient Leak Sealer

XPRESS SEAL is a revolutionary refrigerant leak sealant designed to quickly and effectively seal leaks without damaging system lines or valves. Its unique formula travels with refrigerant gas, ensuring rapid detection and sealing of leaks.

Key Features and Benefits:
  • Fastest-Acting Leak Sealer: Offers rapid leak detection and sealing for efficient repairs.
  • Permanent Seal: Creates a long-lasting seal to prevent refrigerant leaks.
  • Safe Formulation: Does not contain harmful chemicals that can cause eye damage.
  • Advanced Technology: Travels with refrigerant gas for effective sealing.

XPRESS SEAL is the ideal choice for professionals and homeowners seeking a reliable and efficient solution for refrigerant leaks. Its powerful performance and safety features make it a valuable asset for maintaining the performance and efficiency of HVAC systems.

Part Number;     Size
  • XPS-SS                              Up to 1.5 Ton
  • XPS-5T                              1.5-5 Ton
  • XPS 10T                            2-10 Ton
  • XPS-15T                            6-15 Ton
  • XPS-30T                           16-30 Ton
  • XPS-60T                           31-60 Ton
  • XPS-125T                         61-125 Ton
  • XPS-250T                        126-250 Ton

Compatible with all refrigerants, excluding ammonia.

Directions:
Traditional Method:
  1. Power On: Turn on the AC system and verify it’s running.
  2. Connect Xpress Inject: Connect the Xpress Inject to the low-side service port.
  3. Connect Refrigerant Hose: Attach the manifold refrigerant hose to the refrigerant supply tank. Ensure both high and low-side valves are closed.
  4. Purge Hose: Purge the low-pressure hose before connecting to Xpress Inject.
  5. Open Valve and Monitor: Open the low-side valve and watch for the tube to clear. Close the valve and turn off refrigerant gas once the tube is clear.
  6. Disconnect and Recharge: Disconnect the low-side hose from Xpress Inject, install the service port cap, and run the AC unit for at least one hour.
Directions for Direct Inject Hose:
  1. Power On and Check: Turn on the AC system and verify the compressor is running and the system is fully charged.
  2. Connect Hose: Connect the “A” side of the hose to the high-pressure service port, ensuring the ball valve is closed.
  3. Connect Injector Tube: Carefully thread the male end of the injector tube into the “B” side of the hose. Avoid depressing the valve.
  4. Remove Air: Crack open and close the ball valve to remove air from the hose.
  5. Connect Injector Tube: Thread the injector tube into the “B” side of the hose.
  6. Open Valve and Inject: Open the ball valve and let refrigerant flow through. Then, inject the product into the system.
  7. Close Valve and Disconnect: Close the ball valve and disconnect the hose and injector from the unit.
  8. Release Charge: Remove the tube from the “B” side of the hose and open the ball valve to release the charge.
Using the Direct Inject Gun:
  1. Power On: Turn on the AC system and verify it’s running.
  2. Connect Xpress Inject: Connect the Xpress Inject to the Direct Inject Gun, and then connect the other end to the low-side service port.
  3. Inject Sealant: Briefly pull the trigger to inject the sealant into the system.
  4. Disconnect and Run: Disconnect the empty tube from the low-side port and install the service port cap. Run the AC unit for at least one hour.

Note: For optimal results, follow these directions carefully and consult the product label for additional information.

 

DANGERS & PRECAUTIONS:

Read and understand the product’s label and Safety Data Sheet. May be fatal if swallowed and enters airways. Highly flammable liquid and vapor. May cause skin irritation. Toxic to aquatic life. DO NOT use it in any manner for which it was not designed. Always wear PPE (Personal Protective Equipment) when servicing HVAC equipment. Do NOT handle or use this product until all safety precautions have been read and understood. Keep away from heat/sparks/open flame/hot surfaces – NO SMOKING! Do not breathe dust/fume/gas/mist/vapors/ spray. Wash hands and arms thoroughly after handling. Use only outdoors or in a well-ventilated area. Avoid release to the environment. Wear protective gloves/clothing/face/ eye protection.

 